一种基于ADBMS6830的液冷电池管理系统设计
电子技术应用
靳鹏飞,赵群辉,王淇森,李莎莎,王瑞
许继电气股份有限公司
摘要: 针对储能电池单体电压采样和电池簇电压、电流、绝缘检测的高精度要求,提出了一种基于ADBMS6830的液冷电池管理系统,该系统采用ADI先进AFE ADBMS6830和TI的精密ADC ADS1120实现电池电压信息、簇电压、簇电流以及系统绝缘阻抗检测的精确测量。测试结果表明,电池电压采集在标准电压3.3 V全温度范围内能够实现±2 mV以内的测量误差,簇电压采集能够实现±0.06%的测试精度,簇电流采集能够实现±0.06%的测试精度,绝缘检测能够实现±5%的测试精度。所提出的液冷电池管理系统在组串式5 MWh液冷储能系统进行了应用,验证了系统的可实施性。
中圖分類號(hào):TM912 文獻(xiàn)標(biāo)志碼:A DOI: 10.16157/j.issn.0258-7998.257146
中文引用格式: 靳鵬飛,趙群輝,王淇森,等. 一種基于ADBMS6830的液冷電池管理系統(tǒng)設(shè)計(jì)[J]. 電子技術(shù)應(yīng)用,2026,52(3):106-112.
英文引用格式: Jin Pengfei,Zhao Qunhui,Wang Qisen,et al. Design of a liquid cooled battery management system based on ADBMS6830[J]. Application of Electronic Technique,2026,52(3):106-112.
中文引用格式: 靳鵬飛,趙群輝,王淇森,等. 一種基于ADBMS6830的液冷電池管理系統(tǒng)設(shè)計(jì)[J]. 電子技術(shù)應(yīng)用,2026,52(3):106-112.
英文引用格式: Jin Pengfei,Zhao Qunhui,Wang Qisen,et al. Design of a liquid cooled battery management system based on ADBMS6830[J]. Application of Electronic Technique,2026,52(3):106-112.
Design of a liquid cooled battery management system based on ADBMS6830
Jin Pengfei,Zhao Qunhui,Wang Qisen,Li Shasha,Wang Rui
Xu Ji Electric Technology Center Device Platform Department
Abstract: In view of the high precision requirements for energy storage battery cell voltage sampling and battery cluster voltage, current, and insulation detection, this paper presented a liquid cooled battery management system based on ADBMS6830, which uses ADI's advanced AFE ADBMS6830 and TI's precision ADC ADS1120 to achieve accurate measurement of battery voltage information, cluster voltage, cluster current, and system insulation impedance detection. The test results show that the battery voltage acquisition can achieve measurement errors within±2 mV within the full temperature range of standard voltage 3.3 V, cluster voltage acquisition can achieve testing accuracy of±0.06%, cluster current acquisition can achieve testing accuracy of ±0.06%, and insulation detection can achieve testing accuracy of ±5%. The proposed liquid cooled battery management system has been applied in a series 5 MWh liquid cooled energy storage system, verifying the feasibility of the system.
Key words : battery management system;battery management unit;temperature collection;insulation testing;ADBMS6830
引言
儲(chǔ)能電站對(duì)于保障電力系統(tǒng)的穩(wěn)定運(yùn)行,優(yōu)化資源配置,促進(jìn)可再生能源的利用,提高電力系統(tǒng)的效率,降低運(yùn)營(yíng)成本以及提高供電可靠性等方面都具有重要的作用[1-3]。電池管理系統(tǒng)(BMS)能夠?qū)崟r(shí)監(jiān)控儲(chǔ)能電池的狀態(tài)參數(shù),包括單體電池電壓、電池溫度、電池回路電流、電池組端電壓、電池系統(tǒng)絕緣電阻等,并進(jìn)行分析計(jì)算,得到更多的系統(tǒng)狀態(tài)評(píng)估參數(shù),根據(jù)特定保護(hù)控制策略實(shí)現(xiàn)對(duì)儲(chǔ)能電池本體的有效管控,保證整個(gè)儲(chǔ)能電池單元的安全可靠運(yùn)行。隨著儲(chǔ)能電站的快速發(fā)展和普及,電池管理系統(tǒng)成為了儲(chǔ)能電站中不可或缺的組成部分。電池管理系統(tǒng)主要負(fù)責(zé)監(jiān)測(cè)、控制和保護(hù)儲(chǔ)能電站中的電池系統(tǒng),確保電池的穩(wěn)定性、安全性和壽命[4-6]。因此,開發(fā)一套高精度高效可靠的電池管理系統(tǒng)變得至關(guān)重要,以滿足電力儲(chǔ)能市場(chǎng)的需求,并提升電池系統(tǒng)的性能和可靠性。
本文詳細(xì)內(nèi)容請(qǐng)下載:
http://ihrv.cn/resource/share/2000007013
作者信息:
靳鵬飛,趙群輝,王淇森,李莎莎,王瑞
(許繼電氣股份有限公司,河南 許昌 461000)

此內(nèi)容為AET網(wǎng)站原創(chuàng),未經(jīng)授權(quán)禁止轉(zhuǎn)載。